Puretratech · PT89KCGACS

General-Purpose PES Membrane Capsule Filter for Microorganism Retention

Low-protein-binding PES capsule filter with a Stäubli vent connection for online integrity testing in bioprocessing and general microorganism-retention applications.

Sterilizing grade: NoSource verifiedEnglish source
Request a quote
Puretratech PT89KCGACS 89 mm Capsule Filters
MODELPT89KCGACSFORMAT89 mm Capsule Filters
SKU / ModelPT89KCGACS
MOQ12 pcs
Lead time20 days
Country of originChina
HS code8421999090
Support / warranty3 years

01 / 09

PRODUCT OVERVIEW

Designed for low-binding, high-value fluid filtration

This full-size capsule filter features a Stäubli vent connection that enables online integrity testing for reliable filter validation.

A single-layer hydrophilic polyethersulfone (PES) membrane in an all-polypropylene, compact, ready-to-use construction provides broad chemical compatibility, high flow at low pressure drop and low extractables.

The low protein-binding characteristics of PES minimize membrane adsorption, making this filter a suitable choice for valuable protein solutions such as vaccines and biologicals.

02 / 09

KEY FEATURES

Construction and performance

  • Low-adsorption hydrophilic PES membrane
  • Stäubli vent connection for online integrity testing
  • Compact, ready-to-use all-polypropylene construction
  • Broad chemical compatibility
  • High flow with low pressure drop
  • Low extractables for bioprocessing applications

03 / 09

APPLICATIONS

Typical process uses

  • Cell culture media
  • Large-volume parenterals (LVPs)
  • Pharmaceutical bulk chemical solutions
  • Diagnostics
  • Blood and serum fractions
  • Purified water
  • Beer, wine and spirits
  • Juice and soft drinks
  • Bottled water

04 / 09

MATERIALS

Materials of construction

Structured text sourced from the submitted workbook.

ComponentMaterial / method
Filter membranePolyethersulfone (PES)
Media supportPolypropylene (PP)
End capsPolypropylene (PP)
Inner corePolypropylene (PP)
Outer cagePolypropylene (PP)

05 / 09

BIOLOGICAL SAFETY

All materials meet the biological-safety requirements of USP Class VI at 121 °C for plastics.

06 / 09

FOOD SAFETY COMPLIANCE

Materials of construction comply with FDA regulations for food and beverage contact use, as detailed in Title 21 of the U.S. Code of Federal Regulations (21 CFR). Materials used to produce the filter media and hardware are safe for use in contact with foodstuffs in accordance with EU 10/2011.

07 / 09

CAPSULE INTEGRITY

Minimum burst pressure: 123.5 psi (8.5 barg)

08 / 09

Integrity Test

Minimum bubble point by pore size. Values are transcribed from the submitted image.

Pore sizeMinimum bubble point
0.05 µm31.9 psig (2.2 bar), IPA
0.1 µm24.7 psig (1.5 bar), IPA
0.2 µm45 psig (3.1 bar)
0.45 µm24 psig (1.7 bar)
0.65 µm19 psig (1.3 bar)
0.8 µm17 psig (1.2 bar)
1.2 µm11.6 psig (0.8 bar)

09 / 09

Product Configuration / Ordering Information

The table uses one dynamic column per code segment and one “company code=product meaning” expression per option. Row count follows the longest column.

Series codePore sizeLengthFittingsVentDrain
KCGACS0X5=0.05µm03=2.5"1HT=1.5" TCS=StäubliS=Stäubli
001=0.1µm05=5"MT=1/2" TCH=Hose BarbH=Hose Barb
002=0.2µm10=10"08H=1/2" Hose Barb
004=0.45µm20=20"12H=3/4" Hose Barb
006=0.65µm30=30"8N=1/2" NPT
008=0.8µm40=40"8NF=1/2" NPT-F
012=1.2µm
030=3.0µm
050=5.0µm
080=8.0µm